VENTILATING UNITS
INSTALLATION INSTRUCTIONS:
1. Install unit according to arrow on housing, this indicates
direction of airflow to outside atmosphere. Unit should be firmly
bolted to booth and duct work to avoid excessive vibration.
2. Arrow on fan indicates proper fan rotation. Make sure motor
is wired to rotate fan properly.
3. Note: Motor is to be mounted on plate provided. Make sure
motor is firmly secured. Adjust plate for proper belt tension.
4. Access door on housing is optional for servicing fan, shaft
and bearings. When mounting unit, make sure the Access
Door is free from any obstruction.
5. All vent units are equipped with (2) two angle iron rings.
BE-54-12 Diameter Ring BE-54-33 Diameter Ring
BE-54-18 Diameter Ring BE-54-43 Diameter Ring
BE-54-24 Diameter Ring
All Paasche Units have sealed ball bearings.
SIZE H.P. AB C DNO. OF HOLES
B12- 1/4 12" 12" 14-1/16" 13-3/16" 4
B18- 1/4, 1/3, 1/2, 3/4 14" 18" 20- 3/32" 19-1/4" 4
B24- 1/2, 3/4, 1, 1-1/2, 2 17" 24" 26-3/32" 25-1/4" 8
B32- 2, 3, 5 19" 33-1/8" 35-3/4" 34-3/4" 8
B42- 3, 5 24" 43-1/4" 45-3/4" 44-3/4" 8
Paasche Airbrush Company
4311 North Normandy Avenue
Chicago, IL 60634-1395
Phone: 773-867-9191 Fax: 773-867-9198
Website: paascheairbrush.com
E-Mail: info@paascheairbrush.com
WARNING: Spray materials may be harmful if inhaled or
allowed to come into contact with skin or eyes. Consult the
product label and Material Safety Data Sheet supplied for the
spray material. Follow all safety precautions. Use in Well
Ventilated Area to remove fumes, dust or overspray.
Maintenance should always be performed by experienced and
trained personnel (lock out-tag out). Regular maintenance
checks for paint residue must be performed to remove
any fire hazard. The fan should be checked for build-up
and kept clean. Paint Filters must be changed frequently.
BEARING & SHAFT ASSEMBLY
FOR B12- THRU B42- VENTS
1. Insert shaft through bearing.
2. Push counterbored side of collar over
inner race of bearing.
3. Lock collar into place with a right turn.
4. Tighten set screw.
Printed in the U.S.A.
INSTRUCTIONS AND PARTS LIST VU-8/31/2011
Supersedes Instructions & Parts List VU-02/10/2009
Page view 0
1 2

Summary of Contents

Page 1 - VENTILATING UNITS

VENTILATING UNITSINSTALLATION INSTRUCTIONS:1. Install unit according to arrow on housing, this indicatesdirection of airflow to outside atmos

Page 2

B12-1/4 H.P. VENT UNIT L/ MOTORSpecify 48 or 56 NEMA FrameAK-26-1/2" Motor Pulley (48)AK-26-5/8" Motor Pulley (56)AK-22-5/8" Fan Pul