INSTRUCTION AND PARTS LIST D100&D100-50, 8/31/2011
Supercedes Instructions & Parts List D100&D100-50, 10/28/2008
WARNING: When a flammable liquid is sprayed, there
may be danger of fire or explosion especially in a closed
room: keep compressor at least 20 feet away from areas
where hazardous concentrations of flammable vapors
are likely to occur. Disconnect power before servicing.
ATTENTION: Lorsqu'un liquide inflammable est
pulverise, il peut y avoir danger d'incendie ou
d'explosion, specialement dans une piece fermee;
garder le compresseur a au moins 20 pieds des
endroits ou des concentrations dangereuses de
vapeurs inflammables sont susceptibles de se
produire. Debrancher avant toute maintenance.
Manufactured in Taiwan for Paasche
Paasche Airbrush Company
4311 North Normandy Avenue
Chicago, IL 60634-1395
Phone: 773-867-9191 Fax: 773-867-9198
Website: paascheairbrush.com
D100 Air Compressor
1/8 HP, 110V, 60Hz, 1.1 AMP, .3 CFM @ 20 P.S.I.,
50 PSI, Shipping Weight: 4.7 kgs (10.6 lbs.)
D100-50 Air Compressor
1/8 HP, 220V, 50Hz, .8 AMP, .3 CFM @ 20 P.S.I.,
55 PSI, Shipping Weight: 4.8 kgs (10.9 lbs.)
OPERATION: OILLESS - NEEDS NO LUBRICATION
The compressor is maintenance free. To avoid malfunctions and
premature wear and tear, the following points should be
observed.
1. WARNING: Plug the power cord into a 110V.-60Hz or 220V.-
50Hz Cycle grounded outlet depending on the Model
purchased. Do not use an adapter to by-pass the grounding
feature. Do not operate compressor in a wet area.
2. Place compressor on a level surface, preferably on the floor.
3. Carrying compressor while operating is not advisable.
4. Do not let the compressor run unnecessarily, i.e. the unit
should be switched off when the airbrush is not being used.
5. Always remove the power cord from the electric outlet when
making adjustment or changing parts.
6. Always provide plenty of ventilation while spraying.
7. Never smoke or eat while spraying.
8. Wear a respirator and eye protection when spraying.
TROUBLE-SHOOTING:
1. Low air flow
Possible causes: What to do:
-Reed valve (#33) -Change the defective air
or air valve (#38) valve plate or air valve
damaged
-Diaphragm (#31) damaged -Change the diaphragm
-6 screws (#42) are too loose -Tighten the screws
-Air hose leaking -Check seal, or change
2. Noisy operation
Possible causes: What to do:
-6 screws (#42) are too tight - Loosen the screws, and
then tighten them equally.
Do not over tighten.
-Bearing fault -Return to Factory.
3. Humming but does not work
Possible causes: What to do:
-6 screws (#42) are too tight -Loosen the screws, and
then tighten them equally.
Do not over tighten.
-Armature fault -Return to the Factory.
4. Does not work
Possible causes: What to do:
-Armature fault -Return to the Factory.
NOTICE:
If you need to disassemble the compressor, take care to note the
position and orientation of the parts to assure the correct re-
assembly.
D100 Air Compressor, 110V.,60Hz.
D100-50 Air Compressor, 220V., 50Hz.
Note:
PLUG
Note:
PLUG
D100 or D100-50 AIR COMPRESSOR PARTS
D3000-31 Diaphragm
D3000-60 Mounting Pad
Optional Items:
R-75AR Filter Regulator
HFM-2-1/4'' Air Manifold
Page view 0